Automatic Thermal Analyzer

Automatic Thermal Analyzer

  • PRODUCT MODEL:HM-HA3

【introduction】Secondary thermal analysis, fully automatic, 30 position

Product details

The fully automatic secondary thermal desorption analyzer excels in both performance and differential thermal analysis. It offers high-precision weight measurement, a wide monitoring range, and the ability to measure very small samples. Furthermore, the fully automatic secondary thermal desorption analyzer can perform comparative analysis between samples and standard reference materials, providing information about the sample's chemical composition. In terms of thermal stability testing, the analyzer can also obtain sample mass changes and weight loss rates relative to temperature changes, allowing for the assessment of the sample's heat resistance. 

Product Features

1. 10-inch color touch screen, comprehensive and intuitive parameters, perfect online monitoring;

2. Power-on self-test, gas path pressure difference prompt, automatic positioning, and sample tray calibration;

3. 30 sample positions, meeting the needs of a large number of samples;

4. Sample tray tube position program control, enabling detection of specified tube positions;

5. Microcomputer program control function, allowing method parameter settings, real-time animation display of working status and running time;

6. Desorption zone, injection valve, sample transfer tube, and secondary desorption zone are all independently heated and controlled;

7. Fully automatic low-temperature secondary desorption using semiconductor refrigeration;

8. All gas path tubes are passivated;

9. Automatic operation according to method parameters, automatically completing primary desorption, secondary desorption, backflush cleaning, and other procedures;

10. Can simultaneously start the GC and chromatography data processing workstation for rapid startup and analysis;

Technical Specifications 

Primary Desorption Temperature Adjustment Range: Room temperature ~ 400℃, accuracy ±0.5℃, increment 1℃ (adjustable)

Secondary Desorption Temperature Adjustment Range: Room temperature ~ 400℃, accuracy ±0.5℃, increment 1℃ (adjustable), heating rate > 60℃/S

Focusing Cold Trap Temperature Adjustment Range: -35℃ ~ -5℃, accuracy ±0.5℃, increment 1℃ (adjustable)

Sample-related Pipeline Temperature Adjustment Range: Room temperature ~ 240℃ (related to indoor temperature), accuracy ±1℃, increment 1℃ (adjustable)

Six-way Valve Temperature Adjustment Range: Room temperature ~ 200℃, accuracy ±1℃, increment 1℃ (adjustable)

Number of Sample Positions: 30

Sample Tube Specifications: Diameter 1/4 inch, length 3.5 inches

Analysis Accuracy: RSD < 2.5% (related to GC performance and operating techniques)

Dimensions: 550x450x540 (mm)

Net Weight: Approximately 25KG