Secondary Thermal Analyzer

Secondary Thermal Analyzer

  • PRODUCT MODEL:HM-HA2

【introduction】Secondary thermal analysis, automatic water inlet (between fully automatic and semi-automatic), 1 position

Product details

Product Features:

1. 10-inch color touch screen for perfect online monitoring;

2. Simple operation, one-button sample analysis;

3. Semiconductor cooling, no liquid hydrogen required (cold trap temperature down to -35℃);

4. Real-time display of cycle time for each working state;

5. Sample volume can be adjusted by adjusting the injection time for different sample concentrations;

6. Real-time display of set and actual temperatures for each channel;

7. Programmed temperature ramping: 8 stages, programmable;

8. Sample injection and data acquisition run synchronously, greatly reducing timing errors;

9. Sampling, adsorption, desorption, injection, and backflush cleaning are fully automatic;

10. All pipelines use inert treatment technology;

11. Multiple methods can be stored for easy recall, enabling quick startup and analysis;

12. System leak detection function;

Technical Specifications 

Primary Desorption Temperature Adjustment Range: Room temperature~380℃, accuracy ±0.5℃, increment 1℃ (adjustable)

Secondary Desorption Temperature Adjustment Range: Room temperature~380℃, accuracy ±0.5℃, increment 1℃ (adjustable), heating rate >60℃/S

Focusing Cold Trap Temperature Adjustment Range: -35℃~-5℃, accuracy ±0.5℃, increment 1℃ (adjustable)

Sample-related Pipeline Temperature Adjustment Range: Room temperature~240℃ (related to indoor temperature), increment 1℃ (adjustable)

Six-way Valve Temperature Adjustment Range: Room temperature~200℃, accuracy ±1℃, increment 1℃ (adjustable)

Sample Transfer Part Treatment: Optional, adjustable flow rate, temperature and time

(e.g., backflush sample transfer, activation or aging of collection tubes)

Sample Collection Tube Material and Specifications: Stainless steel, quartz glass, specifications (optional)

Trap Tube Material and Specifications: Stainless steel, quartz glass, elastic quartz capillary, etc. (optional)

Primary Thermal Desorption Flow Rate: 0~100 ml/min continuously adjustable (with indicator)

Gas Path and Related Components Pressure: >0.4MPa

Analytical Accuracy: RSD < 2.5% (related to GC performance and operating techniques)

Linearity: Generally achievable at 0.999 under selected sample groupings and corresponding operating conditions

Instrument dimensions/weight: 480x240x540 mm / 20 kg